Installing more than one Frontline hob
Additional parts: cross bar(s), heat resistant silicon, rubber block, shav-
ing blade.
3 Only use special heat-resistant silicon.
Cut-out section
Distance from the wall: at least 50 mm
Depth:490 mm
Width: The widths of all appliances to be built-in are added together,
minus 20 mm (see also “Overview of all appliance widths”)
Example:
Installing more than one appliance
1. Work out the size of the cut-out section and saw it out.
2. Remove Frontline strip from the appliances by hand (magnetic fasten-
ing).
3. Lay the appliances one at a time on something soft (for example a
blanket) with the underside facing upwards.
4. Screw / clip fixing plates / retaining grips into the appropriate holes in
the protective boxes.