Aeg-Electrolux KB9820E-M Manuel d'utilisateur Page 50

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 60
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 49
Installation instructions
CAUTION!
The new appliance may only be installed and connected by a registered installation engineer.
Please comply with this instruction. If you do not, any damage resulting is not covered by
the warranty.
To prevent future hazards, damaged mains cables must only be replaced by a qualified
electrician.
Safety instructions for the installer
The set-up of the electrical installation is arranged so that the appliance can be isolated
from the mains with a minimum 3mm all-pole contact separation.
Suitable separation devices include e. g. cut-outs, fuses (screw fuses are to be taken out
of the holder), RCD's and contactors.
The site must provide a connection to the electrical supply by means of a socket that is
accessible and outside the configuration space.
The installer must provide anti-shock protection.
The built-in unit must meet the stability requirements of DIN 68930.
Cable type of H05BB-Tmax rating of 90C (or higher) must be used as the mains con-
necting cable. Refer to the rating label on the appliance for voltage and power specifi-
cations.
Ensure voltage of the supply is within these limits, and that the wire is sized suitably in
accordance with local wiring rules to suit the appliance power rating.
50
Vue de la page 49
1 2 ... 45 46 47 48 49 50 51 52 53 54 55 ... 59 60

Commentaires sur ces manuels

Pas de commentaire