Building-in under kitchen counter
Securing the appliance to the cabinet
The cable
Cable types applicable for installation or replacement: H07 RN-F, H05 RN-F, H05 RRF, H05
VV-F, H05 V2V2-F (T90), H05 BB-F.
For the section of the cable refer to the total power (on the rating plate) and to the table:
Total power Section of the cable
maximum 1380 W 3 x 0,75 mm²
maximum 2300 W 3 x 1 mm²
maximum 3680 W 3 x 1,5 mm²
The hearth cord (green/yellow cable) must be 2 cm longer than phase and neutral cables
(blue and brown cables).
min. 550
560-570
593
80-100
A