Instructions for the Installer
The instructions given below are
designed specifically for a qualified
installer and should aid him or her to
perform all installation, adjustment,
and maintenance operations with
absolute precision and in compliance
with all current legislation and
regulations. We strongly recommend
that all operations for the installation
of the appliance be carried out by
Qualified Personnel in accordance with
existing rules and regulations.
Electrical connection
Prior to making the electrical connection, make
sure that:
the protection fuse and the domestic
wiring system are suitable to carry the total
electric load of the oven (see rating plate);
your domestic wiring system has an
efficient earth connection in compliance with
rules and laws in force;
the wall socket or the omnipole switch
used for the electrical connection can easily
be reached after the oven is built in.
The appliance is supplied with a connection
cable incorporating a standard plug, suitable for
the total electric load shown on the rating plate.
The plug is to be inserted into a suitable wall
socket. If you require a direct connection to the
electric network (mains), it will be necessary to fit
between the appliance and the mains an
omnipole switch, with a minimum gap between
contacts of 3 mm, suitable for the required load
and in compliance with rules in force. The green
& yellow ground wire must not be interrupted by
the switch and it should be 2-3 cm. longer than
the other cables.
Terminal block
The oven is fitted with an easily accessible
terminal block which is designed to operate
with a single-phase power supply of 230 V.
Letter L - Live terminal
Letter N - Neutral terminal
or E - Earth terminal
The mains cable and plug as supplied are to
be connected to a shockproof socket (230 V~,
50 Hz). The shockproof socket must be installed
in accordance with the regulations.
The following types of mains cable are
suitable, taking the necessary rated cross section
into account: H07 RN-F, H05 RN-F, H05 RR-F,
H05 VV-F, H05 V2V2-F (T90), H05 BB-F.
The connection cable must in any case be
laid out so that at no point does it reach 50°C
(over room temperature).
After the connection has been carried out,
the heating elements must be tested by being
operated for about 3 minutes.