2. The other end of the inlet hose which
connects to the machine can be turned
as showed in the picture.
Do not place the inlet hose down-
wards. Angle the hose to the left or
right depending on the position of
your water tap.
3. Set the hose correctly by loosening the
ring nut. After positioning the inlet
hose, be sure to tighten the ring nut
again to prevent leaks.
The inlet hose must not be lengthened. If it is too short and you do not wish to move the
tap, you will have to purchase a new, longer hose specially designed for this type of use.
Installation should comply with local water authority and building regulations require-
ments. A minimum water pressure of 0.05 MPa is required for safe operation of the appli-
ance.
Before connecting up the machine to new pipework or to pipework that has not been used
for some time, run off a reasonable amount of water to flush out any debris that may have
collected in the pipes.
Water drainage
The end of the drain hose can be positioned in three ways:
1. Hooked over the edge of a sink using the plastic hose guide supplied with the ma-
chine.
In this case, make sure the end cannot come unhooked when the machine is emptying.
This could be done by tying it to the tap
with a piece of string or attaching it to
the wall.
2. In a sink drain pipe branch. This branch
must be above the trap so that the bend
is at least 60 cm above the ground.
3. Directly into a drain pipe at a height
of not less than 60 cm and not more
than 90 cm.
The end of the drain hose must always be
ventilated, i.e. the inside diameter of the
drain pipe must be larger than the outside
diameter of the drain hose.
The drain hose must not be kinked.
30 Installation